タイトル: Observation of the expansion behavior and quantitative evaluation of elastic recoil of a balloon-expandable stent in three dimensions using a Micro-CT system
著者: Mori, Futoshi
Nakayama, Toshio
Matsuzawa, Teruo
Ohta, Makoto
キーワード: Three dimensional
Micro-CT
Expansion behavior
Elastic recoil of stent
Balloon-expandable stent
発行日: 2012
出版者: IOS Press
誌名: Technology and Health Care
巻: 20
号: 4
開始ページ: 305
終了ページ: 315
DOI: 10.3233/THC-2012-0680
抄録: Percutaneous transluminal coronary angioplasty (PTCA) with stent implantation is widely used for the treatment of coronary stenosis. However, restenosis after stent implantation frequently reported by intravascular ultrasound evaluation. This may occur because of the reduced luminal area after implantation, insufficient stent expansion, or by the elastic recoil of the stent (ERS). Quantitative evaluation of stent expanding should provide further information on how to decrease the incidence of re-stenosis. Many previous studies have observed stent properties in 2D. However, the stent geometry is changed in 3D space, and 3D measurements will provide further information on factors such as the risk for asymmetric ERS. We performed 3D reconstruction using high spatial resolution images obtained with a Micro-CT system to observe the 3D expansion behavior of a test stent and quantitatively evaluate ERS. The expansion behavior of each structural component of the stent varied, as did the ERS and eccentricity. ERS ranged from 2.4% to 9.2% during observation form proximal and distal positions in each component. The greatest difference in ERS between 2D and 3D measurements was 5.2%. 3D measurements provide more information on ERS than 2D measurements. Our result shows the importance of the observation, and the evaluation by three dimensions.
Rights: This is the author's version of a work accepted for publication by IOS Press. Reprinted from Technology and Health Care, 20(4), Futoshi Mori, Toshio Nakayama, Teruo Matsuzawa, Makoto Ohta, Observation of the expansion behavior and quantitative evaluation of elastic recoil of a balloon-expandable stent in three dimensions using a Micro-CT system, 305-315, Copyright 2012, with permission from IOS Press. http://dx.doi.org/10.3233/THC-2012-0680
URI: http://hdl.handle.net/10119/11504