Title: Blood Flow Simulation System with Interaction between Blood Flow and Blood Vessel Wall using Image Based Cartesian Grid
Authors: KUMAHATA, Kiyoshi
WATANABE, Masahiro
MATSUZAWA, Teruo
Keywords: Blood Vessel
Cartesian Grid
Voxel
Medical Image
Fluid Structure Interaction
Issue Date: 2008
Publisher: 日本機械学会
Magazine name: Journal of Biomechanical Science and Engineering
Volume: 3
Number: 2
Start page: 85
End page: 100
DOI: 10.1299/jbse.3.85
Abstract: For the simulation of the fluid-structure interaction (FSI) between the blood flow and blood vessel walls, we have examined the voxel-based FSI method. This method uses a Cartesian grid, called voxel, made from medical images. Further, we have tested the accuracy and reliability of this simple method and have observed its features. In this document, we discuss the background, kinetic models of the blood vessel, a numerical method, and the result of an experiment conducted using an artificial identical shape and an actual realistic shape.
Rights: Copyright (C) 2008 日本機械学会. Kiyoshi KUMAHATA, Masahiro WATANABE, Teruo MATSUZAWA, Journal of Biomechanical Science and Engineering, 3(2), 2008, 85-100. http://dx.doi.org/10.1299/jbse.3.85
URI: http://hdl.handle.net/10119/8503
Material Type: publisher
Appears in Collections:f10-1. 雑誌掲載論文 (Journal Articles)

Files in This Item:

File Description SizeFormat
12460.pdf2509KbAdobe PDFView/Open

All items in DSpace are protected by copyright, with all rights reserved.

 


Contact : Library Information Section, Japan Advanced Institute of Science and Technology