Title: Pump-Probe Time-Resolved Sum Frequency Spectroscopy of the H-Si(111)1X1 surface
Authors: Thi Thu Hien, Khuat
Miyauchi, Yoshihiro
Mizutani, Goro
Keywords: Sum frequency generation;
Pump-probe technique
Hydrogen
Silicon
Vibration
Issue Date: 2010-02-27
Publisher: The Surface Science Society of Japan
Magazine name: e-Journal of Surface Science and Nanotechnology
Volume: 8
Start page: 89
End page: 92
DOI: 10.1380/ejssnt.2010.89
Abstract: We have performed time-resolved sum frequency (SF) spectroscopy of a H-Si(111)1×1 surface excited by pump visible pulses with the pulse width of ∼30 ps in ultra-high vacuum. Broad non-resonant SF signals as a function of the infrared wavenumber increased soon after the pump light irradiation, and decreased in ∼1 ns. A remarkable change in the intensity and the shape of the peak at 2085 cm^<-1> attributed to the Si-H stretching vibration is observed as a function of the delay time. After the pump light irradiation, the symmetric peak in the SF spectra disappeared at ∼60 ps and recovered gradually with an asymmetric shape.
Rights: Copyright (C) 2010 The Surface Science Society of Japan. Khuat Thi Thu Hien, Yoshihiro Miyauchi, and Goro Mizutani , e-Journal of Surface Science and Nanotechnology , 8, 2010, 89-92. http://dx.doi.org/10.1380/ejssnt.2010.89
URI: http://hdl.handle.net/10119/9076
Material Type: publisher
Appears in Collections:c10-1. 雑誌掲載論文 (Journal Articles)