JAIST Repository >
c. マテリアルサイエンス研究科・マテリアルサイエンス系 >
c10. 学術雑誌論文等 >
c10-1. 雑誌掲載論文 >

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10119/10612

タイトル: Development of Label-Free Impedimetric Hcg-Immunosensor Using Screen-Printed Electrode
著者: Truong, TN Lien
Nguyen, Xuan Viet
Chikae, Miyuki
Ukita, Yoshiaki
Takamura, Yuzuru
キーワード: Human Chorionic Gonadotropin (hCG)
Label-free impedimetric immunosensor
Electrochemical impedance spectroscopy (EIS)
Screen-Printed Electrode
DEP chip
発行日: 2011-09-03
出版者: OMICS Publishing
誌名: Biosensors & Bioelectonics
巻: 2
号: 3
開始ページ: 1000107
DOI: 10.4172/2155-6210.1000107
抄録: Screen-printing (thick-film) technology is well identified as a reliable technique for fabrication of electrodes which can be used as transducer in biosensor, with several advantages including low cost, design flexibility, process automation, good reproducibility and a wide choice of materials. However, the immobilization of antibody molecules is a decisive factor for successful fabrication of immunosensors. Besides, the ability to measure human Chorionic Gonadotropin (hCG) is important in establishing the diagnosis of gestational trophoblastic disease and germ cell tumors. Moreover, Electrochemical Impedance Spectroscopy (EIS) recently has been being chosen as a main detection method because it is label-free, less destructive to the activities of biomolecule and very sensitive with comparable detection limits as optical-based sensor. In this work, a sensitive label-free impedimetric hCG-immunosensor was constructed by using a commercial screen-printing carbon ink electrode (namely Disposable Electrochemical Printed chip) as a basis. The hCG antibody was immobilized via the entrapment technique on the carbon ink electrode of DEP chip using functional molecule, 1-pyrenebutanoic acid, succinimidyl ester. The experimental results exposed that the designed immunosensor is more sensitive than other previously reported immunosensors, in the case of detection limit and linear range for antigen detection. With optimal fabrication parameters, the detection limit for α-hCG was 33 pg/mL in 10mM phosphate buffer saline (PBS) solution containing 1% bovine serum albumine (BSA). Furthermore, the use of inexpensive DEP chip as a basis for these immunosensors will allow simple instrumentation, disposable and portable at low cost. This work also demonstrates a new approach to develop a sensitive and labelfree impedimetric immunosensor based on screen-printed electrode for applications in clinical diagnosis.
Rights: Lien TTN, Viet NX, Chikae M, Ukita Y, Takamura Y (2011) Development of Label-Free Impedimetric Hcg-Immunosensor Using Screen-Printed Electrode. J Biosens Bioelectron 2:107. doi:10.4172/2155-6210.1000107 © 2011 Lien TTN, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
URI: http://hdl.handle.net/10119/10612
資料タイプ: publisher
出現コレクション:c10-1. 雑誌掲載論文 (Journal Articles)

このアイテムのファイル:

ファイル 記述 サイズ形式
17725.pdf2387KbAdobe PDF見る/開く

当システムに保管されているアイテムはすべて著作権により保護されています。

 


お問い合わせ先 : 北陸先端科学技術大学院大学 研究推進課図書館情報係